What the most-cited paragraphs say
1926.1053(b)(1): Ladder extending above the landing
When a portable ladder is used to reach an upper landing, its side rails must extend at least 3 feet above the landing. If the ladder is too short for that, it must be secured at the top to a rigid support and a grabrail or other grasping device must be provided.
Written from the official text on eCFR (title 29 as of 2026-10-05). The official text governs.
Typical abatement evidence for a 1903.19 certification
After a citation under 1926.1053, the employer certifies to OSHA that each cited item was corrected, within 10 calendar days of its abatement date (1903.19(c)(1)). When documents are required, they may include evidence of the purchase or repair of equipment, photographs or video, or other written records (1903.19(d)(2)). Records employers commonly keep for this standard:
- Existing written program or procedure, if one applies
- Relevant training records
- Dated photographs of the cited condition and any corrective work
- Inspection, maintenance or repair records
- Records of corrective actions already taken
Examples only, not a list of what OSHA requires or will accept. Your citation says which items need documents. How abatement certification works · Sample certification letter.
Find your dates
Search the public record by company name or inspection number to see each cited item and its abatement date, or work out a certification due date with the abatement deadline calculator.
Recent public OSHA cases citing 1926.1053
- Pm Construction LLC, inspection 1922009 · issued Oct 16, 2026
- McIntire Construction, Inc., inspection 1898435 · issued Oct 15, 2026
- 69187 - David Fisher, inspection 1898319 · issued Oct 15, 2026
- 161695 - H Jimenez Construction LLC, inspection 1911952 · issued Oct 15, 2026
- 161767 - Vera Brothers Framing LLC, inspection 1912499 · issued Oct 15, 2026
- 161919 - Park Construction of North Carolina, Inc., inspection 1916819 · issued Oct 15, 2026
- Country Fair, Inc. #50, inspection 1900452 · issued Oct 15, 2026
- Hector Felix Roofing LLC, inspection 1921232 · issued Oct 14, 2026
- Jva Roofing LLC, inspection 1911912 · issued Oct 14, 2026
- Jb Construction, inspection 1919952 · issued Oct 14, 2026
- Buchanan Plumbing LLC, inspection 1889334 · issued Oct 13, 2026
- 112140 - Twin Ports Excavating of Duluth, inspection 1920617 · issued Oct 12, 2026
- Israel Martinez, inspection 1897031 · issued Oct 9, 2026
- Fort Wayne Reinforcing, Inc., inspection 1892782 · issued Oct 9, 2026
- Robert Kierce Contracting, Inc, inspection 1906256 · issued Oct 9, 2026
- Constructomax Corporation, inspection 1887565 · issued Oct 9, 2026
- 112113 - Gw Cook Construction Inc, inspection 1919734 · issued Oct 8, 2026
- Moises Contractor LLC, inspection 1896190 · issued Oct 8, 2026
- Mateo's Construction Inc., inspection 1881198 · issued Oct 8, 2026
- Carlos Hernandez, inspection 1918510 · issued Oct 7, 2026
From the U.S. Department of Labor's public enforcement data. Verify each record on OSHA.gov.
Plain-English summary, not legal advice; see 29 CFR 1926.1053 for the official text. Independent software. Not affiliated with OSHA. Not legal advice.